transparente Logo Runtal
381 Vendas | 11 2626-4645 | vendas@Runtal.com.br
 
   
lista de produtos
Baumer

Inductive Sensor for the Ex-Area

Inductive Sensor for the Ex-Area  - NAMUR sensors

  Produtct family Housing Sensing distance max. Features Available types
IFRM 06X

Inductive sensors NAMUR
6,5x25 mm, metal 1,5 mm ATEX
IP 67
Order reference Connection types
IFRM 06X9503 cable 2 m
IFRM 06X9503/P
  cable PUR 5 x 0,14, 2 m
IFRM 08X

Inductive sensors NAMUR
8x50 mm, metal 2 mm ATEX
IP 67
Order reference Nominal sensing distance Sn Housing material Housing length Connection types
IFRM 08X9103 2 mm brass nickel plated 27 mm cable, 2 m
IFRM 08X9501/S35 1,5 mm stainless steel 50 mm connector M8
IFRM 08X9503 1,5 mm brass nickel plated 25 mm cable, 2 m
IFRM 08X9503/S35 1,5 mm stainless steel 41 mm connector M8
IFRM 12X

Inductive sensors NAMUR
12x30 mm, metal 4 mm ATEX
IP 67
Order reference Nominal sensing distance Sn Mounting type Housing length
IFRM 12X9103 4 mm non-flush 34 mm
IFRM 12X9503 2 mm flush 20 mm
IFRM 18X

Inductive sensors NAMUR
18x38 mm, metal 8 mm ATEX
IP 67
Order reference Nominal sensing distance Sn Mounting type Housing length
IFRM 18X9103 8 mm non-flush 38 mm
IFRM 18X9503 5 mm flush 30 mm



Switching sensors

  Produtct family Housing Sensing distance max. Features Available types
IFRM 12
(medium, ATEX)

Inductive proximity switch

12x40 mm, metal 4 mm ATEX
IP 67
Order reference Output circuit
IFRM 12N17X2/L NPN make function (NO)
IFRM 12N37X2/L NPN break function (NC)
IFRM 12P17X2/L PNP make function (NO)
IFRM 12P37X2/L PNP break function (NC)
IFRM 12
(short, ATEX)

Inductive proximity switch

12x30,4 mm, metal 4 mm ATEX
IP 67
Order reference Output circuit
IFRM 12N17X1/L NPN make function (NO)
IFRM 12N37X1/L NPN break function (NC)
IFRM 12P17X1/L PNP make function (NO)
IFRM 12P37X1/L PNP break function (NC)


Distance-measuring sensors

  Produtct family Housing material Mounting type Measuring distance Sd Technical data
IWRM 12

Inductive distance measuring sensor
brass nickel plated quasi-flush 0 ... 4 mm
Linearity error ± 160 µm
Repeat accuracy < 0,01 mm
Temperature drift ± 4 % (Full Scale)
Output circuit current output
Connection types connector M12
Protection class IP 67